Remove all of the old liquid gasket from the water outlet mating surfaces, bolts, and bolt holes.
Clean and dry the water outlet mating surfaces.
Apply liquid gasket (P/N 08C70-K0234M, 08C70-K0334M, or 08C70-X0331S) to the cylinder head mating surface of the water outlet.
NOTE:
Apply liquid gasket about 2.5 mm (0.098 in.)diameter bead along the broken line (A).
Do not install components if 5 minutes or more have passed after applying the liquid gasket. Instead, remove the old residue and reapply the liquid gasket.