Alternator Overhaul
Alternator Brush Inspection
Measure the length of both brushes (A) with a vernier caliper (B).
If either brush is shorter than the service limit, replace the brush holder assembly.
If brush length is OK, go to
Step 14
.
Alternator Brush Length
Standard (New):
10.5 mm (0.41 in.)
Service Limit:
1.5 mm (0.06 in.)