A/T Shift Solenoid Valve Test

  1. Disconnect the connectors from the shift solenoid valves.
  1. Measure the resistance of each shift solenoid valve between the connector terminals and body ground.
    Standard:
    12−25 Ω

    • If the resistance is within the standard, go to Step 21 .
    • If the resistance is out of standard, go to Step 25 .
  1. Connect a jumper wire from the negative battery terminal to body ground, and connect another jumper wire from the positive battery terminal to each solenoid valve terminal individually.
    • If a clicking sound is heard, go to Step 22 .
    • If no clicking sound is heard, go to Step 25 .