M/T Reverse Lockout System Circuit Troubleshooting
Check for continuity between the reverse lockout solenoid 2P connector terminal No. 1 and ECM connector C (49P) terminal No. 27.
Is there continuity?
YES
-
Go to
Step 18
.
NO
-
Repair open in the wire between the reverse lockout solenoid and the ECM.■
Do the reverse lockout solenoid test.
Is the reverse lockout solenoid OK?
YES
-
Check for loose terminals or poor connections at ECM. If necessary,
update the ECM if it does not have the latest software,
or
substitute a known-good ECM,
then recheck. If the trouble goes away with a known-good ECM,
replace the original ECM.
■
NO
-
Repair or replace the reverse lockout solenoid.
■