Inspect the runout by supporting both ends of the mainshaft. Then rotate the mainshaft two complete turns while measuring with a dial gauge. If the runout is more than the service limit, replace the mainshaft.
|
Standard:
|
0.02 mm (0.001 in.) max.
|
|
Service Limit:
|
0.05 mm (0.002 in.)
|
|
|