M/T Reverse Shift Fork Clearance Inspection
Measure the clearance between the reverse idler gear (A) and the reverse shift fork (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.20−0.59 mm (0.008−0.023 in.)
Service Limit:
1.3 mm (0.051 in.)