M/T Change Lever Clearance Inspection

  1. Measure the groove width of the change lever.
    • If the groove width is not within the standard, replace the shift lever.
    • If the groove width is within the standard, replace the select lever.
    Standard:
    15.00−15.10 mm (0.591−0.594 in.)