M/T Countershaft Assembly Clearance Inspection
-
Measure the clearance between 1st gear (A) and the distance collar (B) with a feeler gauge (C).
-
If the clearance is more than the service limit, go to
Step 2
.
-
If the clearance is within the service limit, go to
Step 4
.
|
Standard:
|
0.06−0.16 mm (0.002−0.006 in.)
|
|
Service Limit:
|
0.25 mm (0.010 in.)
|
|
|