Inspect for warpage using a straight edge (A) and a feeler gauge (B). Measure across the pressure plate (C). If the most measurement difference is more than the service limit, replace the pressure plate.
|
Standard (New):
|
0.08 mm (0.003 in.) max.
|
|
Service Limit:
|
0.15 mm (0.006 in.)
|
|
|