DTC 73-14:
Short to Ground in Left Side E-pretensioner Motor
-
-
Turn the ignition switch to LOCK (0), and wait for 10 seconds.
-
Turn the ignition switch to ON (II), and wait for 10 seconds.
-
A function test for ‘‘E-pretensioner forcible operation at the time of a CMS operation'' is carried out with the HDS.
-
-
Turn the ignition switch to LOCK (0).
-
-
Turn the ignition switch to ON (II).
-
-
Turn the ignition switch to LOCK (0), and wait for 10 seconds.
-
Turn the ignition switch to ON (II), and wait for 10 seconds.
-
A function test for ‘‘E-pretensioner forcible operation at the time of a CMS operation'' is carried out with the HDS.
-
-
Turn the ignition switch to LOCK (0).
-
-
Measure the resistance between No. 1 terminal of left side wire harness 2P connector and body ground, and between the No. 2 terminal and body ground. There should be an open circuit or at least 1 MΩ.
|
Is the resistance as specified?
|
|
YES
|
-
|
|
|
NO
|
-
|
Open in the left engine compartment subharness (LHD models), E-pretensioner subharness (RHD models), left side wire harness or left engine compartment wire harness; replace the faulty harness.■
|
|