DTC Troubleshooting: 68-1x
Check for continuity between the No. 1 terminal of the dashboard wire harness 4P connector and the No. 21 terminal of the SRS unit connector A (39P).
Is there continuity?
YES
-
Go to
Step 14
.
NO
-
Open in the dashboard wire harness; replace the dashboard wire harness.■