DTC Troubleshooting: 45-1x

  1. Measure the voltage between No. 1 terminal of SRS floor wire harness 2P connector and body ground, and between the No. 2 terminal and body ground. There should be less than 1.0 V.
Is the voltage as specified?
YES -
Go to Step 13 .
NO -
Short to power in the SRS floor wire harness; replace the SRS floor wire harness.■
  1. Turn the ignition switch to LOCK (0).