DTC Troubleshooting: 34-8x

  1. Measure the voltage between the No. 24 and the No. 25 terminals of SRS unit connector B (39P) and body ground. There should be less than 0.5 V.
Is the voltage as specified?
YES -
Faulty right side curtain airbag; replace the right side curtain airbag. ■
NO -
Short to power in the SRS floor wire harness; replace the SRS floor wire harness.■