DTC Troubleshooting: 31-9x

  1. Check for continuity between the No. 6 and the No. 7 terminals of SRS unit connector B (39P) and body ground.
Is there continuity?
YES -
Short to ground in the SRS floor wire harness; replace the SRS floor wire harness.■
NO -
Faulty left side airbag; replace the left side airbag. ■