Intermittent failure, the system is OK at this time. Check for loose or poor connections between the power seat control unit and the gauge control module.■
From the BODY ELECTRICAL system select menu, select UNIT INFORMATION, and then select CONNECTED UNIT.
Disconnect the gauge control module 32P connector.
Disconnect power seat control unit connector A (40P).
Check for continuity between power seat control unit connector A (40P) No. 39 and No. 40 terminals and the gauge control module 32P connector No. 23 and No. 24 terminals individually.
Is there continuity?
YES
-
Replace the
gauge control module
.■
NO
-
An open in the wire between the gauge control module and the power seat control unit.■