Intermittent failure, the system is OK at this time. Check for loose or poor connections between the door multiplex control unit and climate control unit/heater control unit.■
From the BODY ELECTRICAL system select menu, select UNIT INFORMATION, and then select CONNECTED UNIT to see if the climate control unit/heater control unit is communicating with the HDS.
Is the climate control unit/heater control unit detected?
Disconnect the door multiplex control unit 37P connector.
Disconnect the climate control unit/heater control unit connector B (12P).
Check for continuity between the door multiplex control unit 37P connector No. 33 and No. 35 terminals and the climate control unit/heater control unit connector B (12P) No. 1 and No. 2 terminals individually.
Is there continuity?
YES
-
Replace the climate control unit/
heater control unit
.■