Check for continuity between LKAS control unit 26P connector No. 7 terminal and LKAS camera 10P connector No. 6 terminal.
Is there continuity?
YES
-
Check for loose terminals in the LKAS camera and LKAS control unit connectors, then repair if necessary. If all connections are OK,
replace the LKAS camera.
■
NO
-
Repair an open in the wire between LKAS camera and LKAS control unit.■