DTC Troubleshooting: 51-02, 51-03, 51-06, 51-07
Measure the resistance between EPS control unit connector D (28P) terminals No. 8 and No. 9.
Is the resistance between 12−15 Ω?
YES
-
Go to
Step 10
.
NO
-
Go to
Step 15
.