DTC Troubleshooting: 22-01
Check for continuity between EPS control unit connector D (28P) terminal No. 3 and body ground.
Is there continuity?
YES
-
Repair short to body ground in the wire between the EPS control unit and the ECM/PCM.■
NO
-
Go to
Step 10
.
Short the SCS line with the HDS.
Disconnect the ECM/PCM connector A (44P) or ECM/PCM connector A (49P).