Measure the voltage to ground: There should be battery voltage.
Blown No. 15 (10 A) fuse in the under-hood fuse/relay box
An open in the wire
2
BLK
Under all conditions
Check for continuity to ground: There should be continuity.
Poor ground (G602)
An open in the wire
3
GRN
Inclination sensor off switch ON
Check for continuity to ground: There should be continuity.
Poor ground (G501)
Faulty inclination sensor
An open in the wire
4
PUR
Under all conditions
Connect the No. 1 and No. 4 terminals with a jumper wire: The inclination sensor off switch indicator should come on.
Poor ground (G501)
Faulty inclination sensor
Blown bulb
An open in the wire
5
BLU
Under all conditions
Check for continuity between the terminal and the ultrasonic sensor 3P connector No. 2 terminal, and between the terminal and the alarm control siren 6P connector No. 4 terminal: There should be continuity.