MICS (Driver's and Passenger's MICU) Self-diagnostic Function

NOTE: Use only if the HDS is unavailable.
Test Mode 1
Special Tools Required

MPCS short connector
 07WAZ-0010100
  1. Check the No. 15 (10 A) fuse in the under-hood fuse/relay box and the No. 5 (7.5 A) fuse in the driver's under-dash fuse/relay box. If the fuse is blown, find and correct the cause, then replace the fuse.
  1. Turn the ceiling light switch in ‘‘DOOR'' (middle) position. Close all doors. Turn the ignition switch to ON (II).
    NOTE: If the driver's seat belt is unbuckled, the beeper will beep.
  1. Connect the MPCS short connector (A) to the MICU service check connector (B), and turn the switch (C) on.
  1. After 5 seconds, the ceiling light and ignition key light should come on for 2 seconds, go out, then blink once for 0.2 second. This means that you are in Test Mode 1 of the self-diagnostic function.
  1. About 1 second after step 5, the ceiling light and ignition key light will blink and indicate the DTC, and repeat it every 3 seconds. If there is more than one DTC, the system will indicate them in ascending order, beginning from the DTC with the lowest numerical value.
    DTC
    Condition
    1
    Communication bus line error (BUS OFF)
    3
    The driver's MICU cannot receives signals from the door multiplex control unit.
    5
    The driver's MICU cannot receives signals from the gauge control module.
    6
    The driver's MICU cannot receives signals from the passenger's MICU.