Disconnect the 7P connector from the recirculation control motor.
Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
Connect battery power to the No. 1 terminal of the recirculation control motor, and ground the No. 2 terminal; the recirculation control motor should run, and stop at Fresh. If it doesn't, reverse the connections; the recirculation control motor should run, and stop at Recirculate. When the recirculation control motor stops running, disconnect battery power immediately.
If the recirculation control motor did not run in
Step 2
, remove it, then check the recirculation control linkage and door for smooth movement.