Disconnect the 7P connector from the mode control motor.
Incorrectly applying power and ground to the mode control motor will damage it. Follow the instructions carefully.
-
Connect battery power to the No. 1 terminal of the mode control motor, and ground the No. 2 terminal; the mode control motor should run, and stop at Defrost. If it doesn't, reverse the connections; the mode control motor should run, and stop at Vent. When the mode control motor stops running, disconnect battery power immediately.
-
If the mode control motor did not run in
Step 2
, remove it, then check the mode control linkage and door for smooth movement.
-
Measure the resistance between the No. 5 and No. 7 terminals of the mode control motor. It should be between 4.2 and 7.8 kΩ.
-
Reconnect the mode control motor 7P connector, then turn the ignition switch to ON (II).
-
Using the backprobe set, measure the voltage between the No. 3 and No. 7 terminals.
|
Vent:
|
About 0.5 V
|
|
Defrost:
|
About 4.5 V
|
-
|
|