K24Z3 engine model: Check for continuity between the A/C compressor clutch connector No. 1 and No. 3. If there is no continuity,
replace the thermal protector.
NOTE: The thermal protector will have no continuity above about 122 to 128 °C (252 to 262 °F). When the temperature drops below about 116 to 104 °C (241 to 219 °F), the thermal protector will have continuity.