Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.
-
Be careful when connecting service equipment.
-
Do not breathe refrigerant or vapor.
|
NOTE:
-
If accidental system discharge occurs, ventilate the work area before resuming service.
-
Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
-
Connect an R-134a refrigerant recovery/recycling/charging station (A) to the high-pressure service port (B) and the low-pressure service port (C), as shown, following the equipment manufacturer's instructions.
-
Measure the amount of refrigerant oil removed from the A/C system after the recovery process is completed. Be sure to put the same amount of new refrigerant oil back into the A/C system before charging.
|
|