Special Tools Required
Combination gauge kit 20/−100 kPa
07YAJ-0010610
Tube joint adapter
07410-5790503
-
Disconnect the vacuum hose (A) from the EVAP canister (B) and connect a vacuum pump/gauge (C) to the hose.
-
Start the engine, and let it idle.
NOTE: Engine coolant temperature must be below 55 °C (131 °F).
-
Hold the engine speed at 3,000 rpm (min
−1
) without load (A/T in N or P, M/T in neutral) until the radiator fan comes on, then hold the engine speed to 3,000 rpm (min
−1
).
-
Turn the ignition switch to LOCK (0).
-
Reconnect the vacuum hose to the EVAP canister.
-
Remove the fuel fill cap.
|
|