Connect battery positive terminal to the reverse lockout solenoid 2P connector terminal No. 2, and connect the battery negative terminal to the reverse lockout solenoid 2P connector terminal No. 1.
-
Make sure the reverse lockout solenoid works. If the reverse lockout solenoid does not work, replace it.
NOTE: The inhibitor should be pushed out when applying the current to the solenoid, and the inhibitor shouled be released when no applying the current to the solenoid.
|
|