M/T Change Lever Clearance Inspection

  1. Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance is more than the service limit, go to Step 2 .
    Standard:
    0.05−0.25 mm (0.002−0.010 in.)
    Service Limit:
    0.50 mm (0.020 in.)


  1. Measure the groove width of the change lever.
    • If the groove width is not within the standard, replace the shift lever.
    • If the groove width is within the standard, replace the select lever.
    Standard:
    15.00−15.10 mm (0.591−0.594 in.)