Closing force check:
-
With a shop towel (A) on the leading edge of the glass (B), attach a spring scale (C) as shown.
-
Have an assistant hold the switch to close the glass while you measure the force required to stop it.
-
Read the force as soon as the glass stops moving, then immediately release the switch and the spring scale.
|
Closing force:
|
200−290 N (20−30 kgf, 44−66 lbf)
|
-
-
The gear teeth and the inner cable for breakage and damage. If the gear teeth are broken, replace the motor. If the inner cable is damaged,
remove the frame,
and
replace the cable.
-
-
The opening drag. Go to
Step 4
.
|
|